Data Loading...

2021 SHELVING INSTALLATION INSTRUCTIONS

125 Views
13 Downloads
9.05 MB

Twitter Facebook LinkedIn Copy link

DOWNLOAD PDF

REPORT DMCA

RECOMMEND FLIP-BOOKS

Pest Armor | Universal Installation Instructions

160 LF PEST ARMOR EXCLUSION APPLICATIONS SOLAR PANEL RIDGE VENT FOUNDATION SILL PLATE DON’T JUST REM

Read online »

Nilkamal Cambro Shelving

Corrosion Free Easy to Clean Extremely Strong Shared Post Design Maximizes Space Usage Wide Open & E

Read online »

Zoom Instructions

off using the options at the bottom left of the call screen. Note: You will only be able to see thes

Read online »

EOI Instructions

EOI Instructions Evidence of insurability Instructions for online submission What is EOI and when is

Read online »

Installation and Annual Awards

neighborhood informat ion are subject to change wi thout not ice or obl igat ion. Home shown does no

Read online »

Folding Activity Arch Instructions

Folding Activity Arch Instructions   READ, FOLLOW AND KEEP THESE SAFETY IN

Read online »

Swurl Spinner Instructions

Swurl Spinner Instructions SWURL SPINNER INSTRUCTIONS SS0312 READ, KEEP AND FOLLOW THESE SAFETY INST

Read online »

Smokehouse Installation Checklist

ovenguide

Read online »

Lime - Guide d'installation

- 0.5 cm. La jupe se fixe aux lambourdes avec des vis en prévoyant un jeu de 5 mm aux extrémités dan

Read online »

CWU Presidential Installation 2022

TITLE IX INSTITUTION. FOR ACCOMMODATION EMAIL: [email protected]. Page 10

Read online »

2021 SHELVING INSTALLATION INSTRUCTIONS

SHELVING ASSEMBLY & INSTALLATION I NST RUCT I ONS 202 1

reorder code: 27332

THANK YOU FOR PURCHASING RAECO LIBRARY SHELVING

INDEX

Page

LINEA SHELVING

STATIC SHELVING

4

MOBILE SHELVING

6

Infill panels

8

Solid DUSTCOVERS

10

BAYEND PANELS

12

Shelf assembly

14

WALL STRIPPING

16

EXPRESSIONS SHELVING

22

Every effor t has been made to ensure that the product you purchased is of high quality and inclusive of all hardware. If you require assistance with assembly or need additional hardware, please contact us via email: [email protected] or phone 1300 727 231

SPRINGVALE PUBLIC LIBRARY | VIC

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

2

3

LINEA | STATIC SHELVING

RUBBER MALLET

FINGER PINCH POINT

Applicable for both Single Sided (S/S) and Double Sided (D/S) Linea Shelving

3 Inser t the top joiner lugs into the corresponding joiner slots located at the top of the first post. Pull the opposite post outward slightly, until the lugs of the top joiner slot into place. Using a mallet firmly bang the top cap of the joiner with a rubber mallet on both ends to fix in place.

1 Stand one shelving post upright and inser t the lugs from the bottom joiner into the corresponding slots in the post. Firmly bang the top of the joiner with a rubber mallet to fix it in place.

2 Place the next post in position similar to the first post, inser ting the lugs from the bottom joiner into the slots on the post. Using the mallet firmly bang the top of the joiner to fix it in place.

4 Repeat steps (1-3) for the desired number of bays ‘daisy-chaining’ them together. Once all of the bays are assembled to the desired length, inser t your shelving as required to suit your collection.

tip

tip

Shelving systems 2000mmH and greater require an additional center joiner which should be installed at the same time as the bottom joiner (step 1)

When installing display shelves at the top, remove the plastic post cap, inser t the shelf with the top lug aligned with the top post slot and reinser t the cover cap.

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

4

5

LINEA | MOBILE SHELVING

M8 WRENCH

RUBBER MALLET

FINGER PINCH POINT

3 Inser t the top joiner lugs into the corresponding joiner slots located at the top of the first post. Pull the opposite post outward slightly, until the lugs of the top joiner slot into place. Using a mallet firmly bang the top cap of the joiner with a rubber mallet on both ends to fix in place.

1 Stand the post upright and inser t the lugs from the bottom mobile joiner into the corresponding slots in the post. Firmly bang the top of the joiner with a rubber mallet to lock it into position. Fasten the joiner to the post with the included M8 hex head bolts in both location.

2 Stand the next post up and move it into position similar to the first post, inser ting the lugs from the bottom mobile joiner into the slots on the post and repeat the fastening method of (step 1)

4 Repeat steps (1-3) for a double bay by ‘daisy-chaining’ them together. Once the bays are assembled, inser t your shelving as required to suit your collection.

! Raeco do not recommend connected Linea mobile shelving runs any longer than two bays as it becomes too heavy to move and applies excessive strain on the par ts during relocation.

tip

When relocating mobile shelving bays. Use a Raeco tow handle, that hooks onto the bottom of the shelving post. This ensures an evenly distributed pulling force, reducing any unnecessary strain on components.

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

6

7

Linea | infill panels

CORDLESS DRILL

FINGER PINCH POINT

3 To secure the infill panel, from the back of the bay use a cordless drill and ( 4 ) self tapping 8G x 16mm screws in the holes provided through both the top and bottom joiner.

1

2 Inser t the infill panel on an angle, into the top joiner and slot it down into the bottom joiner. For single sided units ensure it is inser ted on the shelving side of the bay.

Star t with an assembled bay of shelving. If infill panels are being installed into existing shelving, ensure any shelves have been removed and that you have access to both sides of the shelving.

8G x 16mm re-order code: 93000316

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

8

9

Linea | solid DUSTCOVERS

CORDLESS DRILL

Double sided

1815 MM 1 x 7 bay | 4 dust cover panels

1800 MM

900 MM

1815 MM

1 x 3 bay | 2 dust cover panels

SINGLE sided

1815 MM

915 MM

1 x 2 bay | 1 dust cover panel

1830 MM

3

1 Star t by removing and discarding the plastic plugs from the top of the posts. Install the dustcover brackets in the top slots of the post, remembering that end brackets are supplied in sets with a Left & Right side version.

2 Place the timber dustcover on top of the brackets, aligning the edge of the dustcover flush with the Post. For single sided installations, align the rear edge of the dustcover flush with the rear face of the post. For double sided configurations, ensure the panel is aligned centrally.

Intermediate Bracket

END Bracket

Fix the dustcovers in place using the self tapping 8G x 16mm screws provided. (2) per bracket end bracket, in the provided hole locations. Repeat steps 1-3 for opposite sides and adjacent dustcovers.

1 x 1 bay | 1 dust cover panel

Solid Dustcover Sizes Depending on your shelving configuration, there are six different sizes of Raeco standard timber laminate solid dustcovers. Panels sizes that end with either (15 or 30mm) increments are designed to meet flush with a post and are used with end brackets .Where as panels in increments of 900mm match the post centre-to-centre distance and meet up with intermediate brackets.

930 MM

8G x 16mm re-order code: Set of (6) 10013

Set of (4) 10014

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

10

11

Linea | bayend panels

CORDLESS DRILL

3 Align the BEP to the top of the post (or dustcover if dustcovers are fitted). Using either clamps or a helping hand, hold the panel in place and from the internal side of the BEP drive ( 5 ) self tapping 8G x 45mm screws through the previously drilled holes.

1 If installing Bay End Panels ( BEPs ) onto existing shelving, remove the shelves adjacent to the BEP install location for access to the back of the post. Mark ( 5 ) holes equally spaced where

2 Using a cordless drill with a 6mm diameter metal-compatible drill bit, drill right through the post in the previously marked locations. Ensure the drill is held level so to create a horizontal hole. It is advised to use a smaller drill bit as a pilot-guide hole first, prior to the 6mm bit.

! NOTE: Bayend Panels are an aesthetic cladding only and not structural to the shelving. Never attempt to relocate a bay of shelving by pulling or pushing on the BEPs.

indicated with a ( ). NOTE: If timber dustcovers are to be fitted to the shelving, install these FIRST

8G x 45mm re-order code: Set of (5) 10011

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

12

13

Linea | shelf assembly

SCREW DRIVER

linea flat shelf assembly

hangup rail assembly

3 Position the flat shelf above them and press it down in place.The sides of the shelf will sit firmly in the slot on each adjacent bracket. Repeat steps 1-3 for additional shelves.

3

1

2

1

2

Standard linea flat shelves are suppor ted on either end by end brackets or intermediate (middle) brackets depending on the configuration.

Inser t the brackets at the desired height into the shelving post holes, making sure that the brackets are level with each other. *Raeco recommend inserting the bottom shelves first and working your way up to assist in evenly spacing the shelves.

Hangup rail kits consist of three main par ts.The rail, the brackets (L/R)and the rail clamps as pictured above.

Align the components as shown above and then fasten together with the provided 16mm M6 bolts (two per side).

Place hang up bags on the rail lip, a hang up rail can hold a maximum of 45 bags.

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

14

15

wall stripping | floating shelving

TAPE MEASURE

RUBBER MALLET

CORDLESS DRILL

ALIGNING WALL STRIPPING

Mounting to brick & cement walls

TOP

275 mm

TOP

12.5 mm

900 mm 900 mm

900 mm 900 mm

x

275 mm

275 mm

[ X ] mm h

x

BOTTOM

3 Using a post as a guide, mark the hole locations on the wall.The first hole should be 12.5mm down from the TOP of the post with subsequent

3

1 Star t by marking out the desired location and height [ X ] of the wall stripping, ensuring the post centres are 900mm apar t.

2 Wall stripping posts have a TOP and BOTTOM orientation. It is essential that all posts are installed in the correct orientation to maintain shelf alignment.To identify the TOP , find the mounting hole that is 12.5mm from the end of the post.

1

2

Using an impact drill with hammer setting and a 6.5mm masonry bit, drill the previously marked holes 50mm into the wall. *double check all measurements and alignments prior to drilling.

Using a mallet gently tap in the supplied wall anchors into the drilled holes.

Align the posts and fasten to the wall with the provided 10G countersunk screws.

Green Wall Anchor re-order code: 82139 ea

10G x 75mm re-order code: Set of (7) 10017

holes spaced 275mm apar t on alternating sides of the post.

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

16

17

wall stripping | floating shelving

TAPE MEASURE

CORDLESS DRILL

Mounting to PLASTER & STUDDED WALLS

STUD LOCATION

x

275 mm

900 mm 900 mm

900 mm 900 mm

x

275 mm

x

275 mm

x

[ B ] mm h

275 mm

x

275 mm

x

275 mm

x

[ X ] mm h

4

5

3

1

2

tip

Using a cordless drill fasten the battens to the previously marked stud locations in as many points as possible *Number varies depending on stud spacing and length of shelving run.

Align the posts and fasten to the pine battens with the provided 10G

Raeco recommends installation of infill panels to conceal the Pine Battens. Alternatively the battens can be painted in a discrete colour prior to installation.

When mounting floating shelving to plaster walls, additional battens are required to provide a secure mounting surface. Repeat steps 1-3 on (pg. 16) additionally taking measurements of the length of the run of shelving for the required battens [B] .

Pine battens are required for all orders mounted to plasterboard. Pine battens and fixings will need to be sourced by the customer or Raeco cer tified Installer, at an additional cost.

Using a stud finder, mark the stud locations on the wall, these will be used to secure the battens along the length of the wall. Star ting at the top mounting hole, align and mark the battens horizontal position. Repeat this step every 275 mm going down until the bottom post mounting hole.

countersunk screws. 10G x 75mm re-order code: Set of (7) 10017

Raeco recommend: 70 mm x 2 0 mm x 366 0 mm Pine Battens. 10G x 75mm - Timber Screws

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

18

19

WALLSTRIPPING | BEPS & DUST COVERS

top

bottom

3

1

2

Attach the top bracket 711 or ( 713 for dustcovers) in the top slot of the outer most wall strip on either end of the shelving run. Repeat this with the bottom bracket ( 712 ) ensuring it is in the lowest shelving lug.

Align the BEP so that the bottom is level with the bottom of the post, and the rear edge is touching the wall. Screw the 8G x 25mm screws through the holes in both brackets, and through the Nylon Spacers , into the bayend panel. *This step may require additional help or clamps to hold the BEP in position while assembling.

Place the dustcover on top of the 713 top bracket, ensuring its flush at the front with the bayend panel. Fasten in place with the 8G x 16mm screws provided.

8g x 16 mm

8g x 25 mm

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

20

21

expressions | shelf assembly

EXPRESSIONS flat shelf CONFIGURATION

EXPRESSIONS DISPLAY shelf CONFIGURATION

3 Inser t the shelf by sliding it along the pins until it drops into place.The pins will secure the shelf in place via the folded tab on either side of the shelf. Repeat steps 1-3 as required. *Note: the holes in the side of the expressions shelves are for powdercoating and not intended for the pins.

6

1 Expressions shelving bodies have industry standard ( System 32 ) pin suppor t spacing pre-drilled into each unit, allowing full shelf height customisation to suit your collection. Expressions Metal and Timber shelves are both reversible, allowing for either a display or flat shelf configuration.

2

4 To reverse a shelf into a display shelf, simply take out the flat shelf and move the back pin to the middle column of pins. Count ver tically 8 pin holes up and inser t the rear pin.

5 By reversing the shelf, so what was originally the rear lip of the flat shelf, now becomes the front lip to suppor t the collection on display. Align the front pin with its corresponding slot and then press backwards into position with the rear pin.

For Flat Shelf configurations, use the two outer pin holes. Inser t both shelving pins at the same level.

With the flexibility of reversible shelves, you have complete control over the merchandising of your collection, utilising one shelf enables either spine out or face out displays. *Above configuration features 3x ( 89000 ) reversible shelves, one in display configuration two in flat configuration.

Expressions Shelf Pin re-order code: 5 mm x 24 mm (ea.) 85441

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

Raeco Shelving INSTALLATION INSTRUCTIONS 1300 727 231

22

23

CEI PTY Limited Trading as Raeco® ABN 72 006 501 926

75 Rushdale Street Knoxfield VIC 3180 1300 727 231 suppor [email protected] www.raeco.com.au