Data Loading...

Bid Proposal 1093-2 Security Camera Replacement Graphics

98 Views
8 Downloads
7.41 MB

Twitter Facebook LinkedIn Copy link

DOWNLOAD PDF

REPORT DMCA

RECOMMEND FLIP-BOOKS

Bid 1093 - Security Replacement Project at OCS - Invitation…

or prices set forth in the Proposal

Read online »

Bid Proposal No. 1101 - Addendum No. 2

2020 CCAC Location Overview Photo Log 3 1000 McKee Rd Oakdale, PA 15071

Read online »

Bid Proposal 1102 - Addendum No. 1

LF Contractors may bid on Base Bid #1 only or Base Bid #2 only or both. CCAC shall have the right

Read online »

Bid 1101

21 Project Labor Agreement February 15, 2011 COMMUNITY COLLEGE OF ALLEGHENY COUNTY 800 ALLEGHENY AVE

Read online »

CCAC Bid 1096 - Invitation to Bid

Approval. a) Prior to the commencement of any work or services under this Contract, Professional sha

Read online »

BIC Graphics

BIC Graphics writing instrumen The Best Brands in the Business 2019 technology WARDS & RECOGNITION o

Read online »

Bid 1102

or prices set forth in the Proposal

Read online »

CCAC Bid 1098 - Invitation to Bid

purchase-terms-and-conditions.pdf PAGE 9

Read online »

CCAC Bid 1100 - Invitation to Bid

purchase-terms-and-conditions.pdf + CISCO SYSTEMS, INC. LETTER OF AUTHORIZATION (LOA) - CUSTOMER CON

Read online »

Proposal 3130

or foodservice program that will make high quality food and beverage products available for purchase

Read online »

Bid Proposal 1093-2 Security Camera Replacement Graphics

3

1

2

4

D

COMMUNITY COLLEGE OF ALLEGHENY COUNTY SECURITY CAMERA REPLACEMENT PROJECT

C

SITE LOCATION

B

A

HFL 2021-2019

3

4

1

2

3

1

2

4

O C S B U I L D I N G

D

EXISTING 1-1/2" POWER AND 1-1/2" SIGNAL CONDUITS

N . L I N C O L N A V E .

EXISTING (2) 4" CONDUITS

KEYNOTES: 1. REMOVE EXISTING CAMERA AND CABLE TO BUILDING THEN TO SOURCE - KEEP CONDUIT (ATTACHED TO GUIDE RAIL). CONDUIT ON GUIDE RAIL BECOMES SPARE. 2. REPLACE EXISTING CAMERA WITH NEW INTERCOM CAMERA 3. REMOVE EXISTING INTERCOM - TAG WIRE AS SPARE - PROVIDE COVERPLATE. 4. REFERENCE DETAILS 1,2,3 ON SHEET E504.

EMERGENCY PHONE ETR

ETR

ETR

ETR

ETR

J

1

1

EXISTING HANDHOLE HH#1

EXISTING EXIT GATE

C

EXISTING (2) 4" CONDUITS

ETR

EXISTING PULL BOX WITH GATE PANEL

ETR

ETR

ETR

ETR

EXISTING (3) 1" CONDUITS

ETR

2

IC EXT

EXISTING ENTRANCE GATE

3

1

1

1

ETR

270°

ETR

ETR

ETR

4

ETR EXT FOUR EXISTING

CAMERAS TO REMAIN

B

EXISTING LIGHT POLE TYPICAL

EXISTING POWER HANDHOLE

EXISTING HANDHOLE HH#2

CCAC PARKING LOT SITE PLAN - SECURITY

1

0

10'

20'

40'

Scale: 1" = 20'-0"

A

CALL BEFORE YOU DIG! PENNSYLVANIA LAW REQUIRES 3 WORKING DAYS NOTICE FOR

SCALE: 1" = 20'-0"

CONSTRUCTION PHASE AND 10 WORKING DAYS IN DESIGN STAGE - STOP CALL

POCS SERIAL NUMBER

SYSTEM, INC.

HFL 2021-2019

3

4

1

2

3

1

2

4

SYMBOL & ABBREVIATION SCHEDULE

NOTES:

POWER LEGEND

GENERAL NOTES - ELECTRICAL

MISCELLANEOUS ELECTRICAL LEGEND

ABBREVIATIONS

D

ELECTRICAL PANEL BOARD - SURFACE MOUNTED

A

AQUASTAT - SUPPLIED BY OTHERS, WIRED BY EC

ELECTRICAL PANEL BOARD - RECESSED

BB

BACK BOX

MULTI-OUTLET ASSEMBLY (RATING AS NOTED)

CB

POWER ENCLOSED CIRCUIT BREAKER

1

INDICATES NOTES ELSEWHERE

EMERGENCY POWER OFF

EPO

Ø

PHASE

H

HUMIDISTAT - SUPPLIED BY OTHERS, WIRED BY EC

BUSWAY

R

RELAY

SWITCH LEG

T

TRANSFORMER

BRANCH CIRCUIT

WS

PWR - WATOR SENSOR

SWITCHED CIRCUIT

FINAL CONNECTION BY EC TO EQUIPMENT

HOMERUN TO PANEL BOARD - 3 #12-3/4"C UNO

COMBINATION DISCONNECT SWITCH AND STARTER

CROSS HATCHING INDICATES EQUIPMENT AND/OR WIRING TO BE RENDERED DEAD AND REMOVED BY EC.

FUSED DISCONNECT SWITCH

C

NON-FUSED DISCONNECT SWITCH

MAGNETIC MOTOR STARTER

ELECTRIC THERMOSTAT BY OTHERS UNLESS NOTED OTHERWISE AND WIRED BY EC

RECEPTACLES LEGEND

M

MOTOR

AB

VOLTAGE DROP NOTE:

B

· · ·

A

HFL 2021-2019

3

4

1

2

3

1

2

4

1. ALL EXPOSED CABLE SHALL BE RUN IN CONDUIT, ON EXISTING CABLE TRAY OR SECURED TO CABLE TRAY UTILIZING J-HOOKS UNO. FIELD COORDINATE ALL CONDUIT ROUTES. PROVIDE ALL SUPPORT MATERIALS AND HARDWARE FOR A COMPLETE INSTALLATION. PROVIDE JUNCTION 2. FIELD COORDINATE ALL FINAL CONDUIT SLEEVE AND PENETRATION LOCATIONS TO AVOID ANY EXISTING OBSTRUCTIONS. SEAL ALL THRU WALL/FLOOR PENETRATIONS AS REQUIRED PER IBC. 3. USE OF CABLE ZIP TIES TO PREVENT OVER TIGHTENING AND DAMAGE TO CABLES IS PROHIBITED. 4. ALL CABLES ARE TO BE ROUTED TO RACK G08 ON THE THIRD FLOOR IN THE >Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16